Publications des scientifiques de l'IRD

Monleau M., Butel Christelle, Delaporte Eric, Boillot F., Peeters Martine. (2010). Effect of storage conditions of dried plasma and blood spots on HIV-1 RNA quantification and PCR amplification for drug resistance genotyping. Journal of Antimicrobial Chemotherapy, 65 (8), p. 1562-1566. ISSN 0305-7453.

Titre du document
Effect of storage conditions of dried plasma and blood spots on HIV-1 RNA quantification and PCR amplification for drug resistance genotyping
Année de publication
2010
Type de document
Article référencé dans le Web of Science WOS:000280018400002
Auteurs
Monleau M., Butel Christelle, Delaporte Eric, Boillot F., Peeters Martine
Source
Journal of Antimicrobial Chemotherapy, 2010, 65 (8), p. 1562-1566 ISSN 0305-7453
Dried blood spots (DBS) and dried plasma spots (DPS) are easy to collect and store, and have been successfully tested as an alternative to plasma for performing virological analyses. Adequate storage conditions still need to be established and cell-associated proviral DNA in DBS can contribute to the amplified products. We evaluated these two parameters. Residual samples from 34 HIV-1-infected patients [mean viral load (VL) = 3.93 log(10) copies/mL] were used to prepare DPS and DBS, then stored at 20 degrees C and 37 degrees C. HIV-1 nucleic acids were extracted, with or without DNase treatments, to perform HIV-1 VL quantification and nested RT-PCR to amplify the reverse transcriptase gene (798 bp). For DBS stored for 3 months at 20 degrees C, VL could be measured for all samples and results were comparable to plasma VL. At 37 degrees C, a slight decrease was observed after 2 and 3 months (0.16 and 0.37 log(10) copies/mL mean difference, respectively). For DPS, a significant decrease in VL (0.70 and 1.07 log(10) copies/mL after 1 and 2 months, respectively) was seen at 37 degrees C, but not at 20 degrees C. PCR amplifications from DPS were only successful for 50% of samples with an initial VL > 10 000 copies/mL after 1 month at 20 degrees C. From DBS, PCR amplifications are possible until 3 months for samples with plasma VL > 5000 copies/mL. VL and PCR results for DBS treated with DNase are close to results obtained for DPS. Virological monitoring is still feasible for DBS after 3 months of storage at 37 degrees C when VL is > 5000 copies/mL, but DNA contributes largely to the final results.
Plan de classement
Entomologie médicale / Parasitologie / Virologie [052]
Identifiant IRD
PAR00006015
Contact