Publications des scientifiques de l'IRD

Thirion Laurence, Dubot Pérès Audrey, Pezzi L., Corcostegui I., Touinssi M., Lamballerie X. de, Charrel R. N. (2020). Lyophilized matrix containing ready-to-use primers and probe solution for standardization of real-time PCR and RT-qPCR diagnostics in virology. Viruses, 12 (2), art. 159 [13 p.].

Titre du document
Lyophilized matrix containing ready-to-use primers and probe solution for standardization of real-time PCR and RT-qPCR diagnostics in virology
Année de publication
2020
Type de document
Article référencé dans le Web of Science WOS:000521256600010
Auteurs
Thirion Laurence, Dubot Pérès Audrey, Pezzi L., Corcostegui I., Touinssi M., Lamballerie X. de, Charrel R. N.
Source
Viruses, 2020, 12 (2), art. 159 [13 p.]
Real-time molecular techniques have become the reference methods for direct diagnosis of pathogens. The reduction of steps is a key factor in order to decrease the risk of human errors resulting in invalid series and delayed results. We describe here a process of preparation of oligonucleotide primers and hydrolysis probe in a single tube at predefined optimized concentrations that are stabilized via lyophilization (Lyoph-P&P). Lyoph-P&P was compared versus the classic protocol using extemporaneously prepared liquid reagents using (i) sensitivity study, (ii) long-term stability at 4 degrees C, and (iii) long-term stability at 37 degrees C mimicking transportation without cold chain. Two previously published molecular assays were selected for this study. They target two emerging viruses that are listed on the blueprint of the WHO as to be considered for preparedness and response actions: chikungunya virus (CHIKV) and Rift Valley fever phlebovirus (RVFV). Results of our study demonstrate that (i) Lyoph-P&P is stable for at least 4 days at 37 degrees C supporting shipping without the need of cold chain, (ii) Lyoph-P&P rehydrated solution is stable at +4 degrees C for at least two weeks, (iii) sensitivity observed with Lyoph-P&P is at least equal to, often better than, that observed with liquid formulation, (iv) validation of results observed with low-copy specimens is rendered easier by higher fluorescence level. In conclusion, Lyoph-P&P holds several advantages over extemporaneously preparer liquid formulation that merit to be considered when a novel real-time molecular assay is implemented in a laboratory in charge of routine diagnostic activity.
Plan de classement
Sciences fondamentales / Techniques d'analyse et de recherche [020] ; Santé : généralités [050] ; Entomologie médicale / Parasitologie / Virologie [052]
Localisation
Fonds IRD [F B010078936]
Identifiant IRD
fdi:010078936
Contact