<?xml version="1.0"?>
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:title>Single column sequential extraction of Ra, Nd, Th, Pa and U from a natural sample</dc:title>
  <dc:creator>Jeandel, C.</dc:creator>
  <dc:creator>Venchiarutti, C.</dc:creator>
  <dc:creator>Bourquin, M.</dc:creator>
  <dc:creator>Pradoux, C.</dc:creator>
  <dc:creator>Lacan, F.</dc:creator>
  <dc:creator>van Beek, P.</dc:creator>
  <dc:creator>/Riotte, Jean</dc:creator>
  <dc:subject>chemical extraction chromatography</dc:subject>
  <dc:subject>isotopes</dc:subject>
  <dc:subject>natural samples</dc:subject>
  <dc:subject>marine</dc:subject>
  <dc:subject>geochemistry</dc:subject>
  <dc:subject>radium</dc:subject>
  <dc:subject>neodymium</dc:subject>
  <dc:subject>thorium</dc:subject>
  <dc:subject>protactinium</dc:subject>
  <dc:subject>uranium</dc:subject>
  <dc:subject>extraction chimique</dc:subject>
  <dc:subject>isotopes</dc:subject>
  <dc:subject>echantillons naturels</dc:subject>
  <dc:subject>geochimie marine</dc:subject>
  <dc:subject>radium</dc:subject>
  <dc:subject>neodyme</dc:subject>
  <dc:subject>thorium</dc:subject>
  <dc:subject>protactinium</dc:subject>
  <dc:subject>uranium</dc:subject>
  <dc:description>A new procedure allowing the sequential extraction of Ra, Nd, Th, Pa and U from the same initial natural sample (sea or river waters, particles, sediments, rocks) is proposed. Extraction recoveries were better than 90%. Procedural blanks ranged from 80 pg (for Nd) to below 1 fg, the detection limit of the MC-ICP-MS used (for Pa); all were negligible compared with the amounts of elements currently determined. Based on classical anionic resins attached to a peristaltic pump allowing precise flow rate control, this procedure allowed a consequent reduction of the sample size, which improved the sampling resolution and reduced the sampling cost. It also ensured a better consistency of the samples for the five tracers.</dc:description>
  <dc:date>2011</dc:date>
  <dc:type>text</dc:type>
  <dc:identifier>https://www.documentation.ird.fr/hor/fdi:010054308</dc:identifier>
  <dc:identifier>fdi:010054308</dc:identifier>
  <dc:identifier>Jeandel C., Venchiarutti C., Bourquin M., Pradoux C., Lacan F., van Beek P., Riotte Jean. Single column sequential extraction of Ra, Nd, Th, Pa and U from a natural sample. 2011, 35 (4),  449-459</dc:identifier>
  <dc:language>EN</dc:language>
</oai_dc:dc>
