Publications des scientifiques de l'IRD

Marchand Pierre, Salles C., Rodier C., Hernandez Frédéric, Gayrard E., Tournoud M. G. (2014). Utilisation et qualification d'un débitmètre à effet doppler (ADC) sur une rivière intermittente. Houille Blanche - Revue Internationale de l'Eau, (5), p. 40-46. ISSN 0018-6368.

Titre du document
Utilisation et qualification d'un débitmètre à effet doppler (ADC) sur une rivière intermittente
Année de publication
2014
Type de document
Article référencé dans le Web of Science WOS:000345254600007
Auteurs
Marchand Pierre, Salles C., Rodier C., Hernandez Frédéric, Gayrard E., Tournoud M. G.
Source
Houille Blanche - Revue Internationale de l'Eau, 2014, (5), p. 40-46 ISSN 0018-6368
Intermittent rivers pose different challenges to stream rating due to high spatial and temporal gradients. Long dry periods, cut by short duration flush flood events explain the difficulty to obtain reliable discharge data, for low flows as well as for floods: problems occur with standard gauging, zero flow period, etc. Our study aims to test the use of an acoustic Doppler current meter (ADC) for improving stream rating curves in small catchments subject to large variations of discharge, solid transport and high eutrophisation levels. The study is conducted at the outlet of the river Vette, a small coastal river (67 km2) located close to the city of Montpellier (France). The low flow period lasts for more than 6 month; during this period the river flow is sustained by effluents from urban sewage systems, which allows development of algae and macrophytes in the riverbed. The ADC device (Sontek ODArgonaut SW) is a pulsed Doppler current profiling system designed for measuring water velocity profiles and levels that are used to compute volumetric flow rates. It is designed for shallow waters (less than 4 meter depth). Its main advantages are its low cost and high accuracy (1% of the measured velocity or 0.05 m/sec, as reported by the manufacturer). The study evaluate the improvement in rating curves in an intermittent flow context and the effect of differences in sensitivity between low and high water level, by comparing mean flow velocity obtained by ADC to direct discharges measurements. The study also report long-term use of ADC device, by considering effects of biofilms, algae and macrophytes, as well as solid transport on the accuracy of the measurements. In conclusion, we show that the equipment is reliable and is able to provide additional information. However we show also that it is always difficult to measure low flow.
Plan de classement
Hydrologie [062]
Description Géographique
FRANCE
Localisation
Fonds IRD [F B010062724]
Identifiant IRD
fdi:010062724